Necessary tools
In order to be able to install firmware, the following tools are required:
- Personal computer with MS Windows
- Network cable to connect the Valuejet wit the pc
- The latest MSA-tool (Mutoh Service Assistance) or VSM-tool (Valuejet Status Monitor)
Detailed instructions how to install the heater firmware, are described in the maintenance manual.
This heater firmware is supported on the following ValueJet series, loaded with the latest main firmware versions on the following models:
| VJ-1204 (only MSA) | VJ-1304 (only MSA) | VJ-1324 | VJ-1324X | VJ-1604 (only MSA) | VJ-1604X (only MSA) |
| VJ-1614 (only MSA) | VJ-1624 | VJ-1624X | VJ-1638 | VJ-1638X | VJ-2638 |
| VJ-2638X | VJ-1948WX |
Important note
|
For more information about all the latest released ValueJet series firmware versions, please check the following series of articles <here>
Current version 1.24
Changes
- Support for new models
Note
To know how to install the new firmware, please refer to the Service manual. The heater firmware should be installed in combination with following engine firmwares:- VJ-1204 series: v2.02 or higher
- VJ-1304 series: v2.01 or higher
- VJ-1304W series: v2.00 or higher
- VJ-1604 series: v3.03 or higher
- VJ-1604X series: v3.03 or higher
- VJ-1614 series: v2.03 or higher
- VJ-1324 series: v3.02 or higher
- VJ-1324X series: v3.02 or higher
- VJ-1624 series: v3.02 or higher
- VJ-1624X series: v3.02 or higher
- VJ-1638 series: v3.09 or higher
- VJ-1638X series: v3.09 or higher
- VJ-2638 series: v3.09 or higher
- VJ-2638X series: v3.09 or higher
- VJ-1948WX series: v1.07 or higher
Version history
1.23
Changes
- Support for new models
1.22
Changes
- Support for new models
Bug fixes
- Falsely detected over current error stopped heating phase
- Falsely detected heater error with water based ink systems
1.21
Changes
- Optimization of smart chip access method
1.20
New & changed features
- In user mode a heater control menu is added
Note
This heater control firmware is needed for vj-1638 and for vj-2638, in both printers, the implementation of the control menu is different. - For vj-1638:
- set 28: heaterctrl
- Normal: default setting, first pre-heater and platen heater reach target, then later, dryer reaches target
- Fixer: reduce waiting time before printing, starts printing when dryer reaches 70% of target temperature
- Dryer: control of dryer is changed so that all the heaters reach target temperature simultaneously
- set 28: heaterctrl
- For vj-2638:
- set 28: heaterctrl
- Ecomode: heater works at reduced current capacity
- Powerful: heater works at full power, temperature increases faster than in ecomode
- Eco/fixer: ecomode, starts printing when dryer reaches 70% of target temperature, this gives reduced waiting time
- Pow/fixer: powerful, starts printing when dryer reaches 70% of target temperature, this gives reduced waiting time
- Eco/dryer: ecomode, control of dryer is changed so that all the heaters reach target temperature simultaneously
- Pow/dryer: powerful, control of dryer is changed so that all the heaters reach target temperature simultaneously
- Ecomode: heater works at reduced current capacity
- set 28: heaterctrl
1.19
Features
This heater control firmware is needed for the upcoming VJ-2638. The first production FW for VJ-2638, v2.04, requires Heater Controll F/W v1.19 or higher.
Uploading firmware on VJ-2638 requires MSA tool Ver.3.0.3.0 higher.
1.18
Changed items
- Ink end countermeasure. The ink end is now detected more correctly.